The lambda value is the thermal conductivity of a material, expressed in W/mK. The lower this value, the less heat is conducted, and the better the material insulates.

The Rd value indicates the thermal insulating capacity of a material layer. The higher the Rd value, the better the insulation.

The Rd value is calculated as follows: Rd = insulation thickness (in m) / lambda value. Depending on the lambda value and thickness of the insulation board, you get the following Rd values for your façade.

Lambda value
0,035
0,027
Thickness of insulation boards
Appearance with joint
Joint-free appearance(3)
Appearance with joint
Joint-free appearance(3)
20 mm(1)
0,57 m²K/W0,71 m²K/W  
30 mm(2)
0,86 m²K/W1,00 m²K/W1,11 m²K/W1,30 m²K/W
40 mm
1,14 m²K/W1,29 m²K/W1,48 m²K/W1,67 m²K/W
60 mm
1,71 m²K/W1,86 m²K/W2,22 m²K/W2,41 m²K/W
80 mm
2,29 m²K/W2,43 m²K/W2,96 m²K/W3,15 m²K/W
100 mm
2,86 m²K/W3,00 m²K/W3,70 m²K/W3,89 m²K/W
120 mm
3,43 m²K/W3,57 m²K/W4,44 m²K/W4,63 m²K/W
140 mm
4,00 m²K/W4,14 m²K/W5,19 m²K/W5,37 m²K/W
160 mm
4,57 m²K/W4,71 m²K/W5,93 m²K/W6,11 m²K/W
180 mm
5,14 m²K/W5,29 m²K/W6,67 m²K/W6,85 m²K/W
200 mm
5,71 m²K/W5,86 m²K/W7,41 m²K/W7,59 m²K/W
220 mm
6,28 m²K/W6,43 m²K/W8,15 m²K/W8,33 m²K/W

(1) Iso-Façade insulation board without tongue and groove, not ATG certified
(2) Not ATG certified
(3) ATG certification limited to single-family homes. Insulation boards without pre-milled joint lines (joint-free appearance) are standard 5 mm thicker than boards with joint lines.